Model |
EGX-600 |
EGX-400 |
Table type |
T slot |
Table size |
610 (W) x 407 (D) mm (24 (W) x 16 (D) in.) |
407 (W) x 305 (D) mm (16 (W) x 12 (D) in.) |
Cutting area |
610 (X) x 407 (Y) x 42.5 (Z) mm (24 (X) x 16 (Y) x 1-5/8 (Z) in.) |
407 (X) x 305 (Y) x 42.5 (Z) mm (16 (X) x 12 (Y) x 1-5/8 (Z) in.) |
Loadableworkpiece
thickness |
Maximum 40 mm (1-9/16 in.) |
XYZ-axis motor |
AC servo motors (DAC-FFP), 3-axis simultaneous control |
Feed rate |
XY-axis: 0.5, 1 to 100 mm/s (0.02 in./s, 0.039 to 3.9 in./s) Z-axis: 0.5, 1 to 50 mm/s (0.02 in./s, 0.039 to 1.9 in./s) |
Acceleration |
0.1 G, 0.05 G |
Software resolution |
0.01 mm/step (0.00039 in./step) |
Mechanical resolution |
XY-axis: 0.003 mm/step (0.00012 in./step) Z-axis: 0.0025 mm/step (0.000098 in./step) |
Spindle motor |
Brushless DC motor, Maximum 72 W |
Spindle speed |
8,000 to 30,000 rpm |
Tool chuck |
Cutter holder (4.36 mm) and collet |
Positioning Accuracy |
± 0.1 % of distance traveled or ± 0.1 mm (± 0.004 in.), whichever is greater (no-load operation) |
Repeatability |
0.05 mm (0.002 in.) or less |
Interface |
Parallel connector (Centronics-compliant), serial connector (RS-232C-compliant), Memory card slot (Compliance
with Multi Media Card), expansion connector 1, expansion connector 2 |
Buffer memory |
2MB (replot buffer: 1.9MB) |
Instruction system |
RML-1 (mode 1, mode 2) |
Power supply |
AC 117 V, 230 V, 240 V ± 10 %, 50/60 Hz |
Power consumption |
3.5 A at 117 V, 1.6 A at 230 V, 1.6 A at 240 V |
Acoustic noise level |
No-load operation: 75 dB (A) or less standby: 45 dB (A) or less (According to ISO 7779) |
Dimensions (main unit) |
995 (W) x 820 (D) x 521 (H) mm (39-3/16 (W) x 32-5/16 (D) x 20-1/2 (H) in.) |
795 (W) x 719 (D) x 521 (H) mm (31-5/16 (W) x 28-5/16 (D) x 20-1/2 (H) in.) |
Weight (main unit) |
64 kg (141 lb.)T slot |
51 kg (112 lb.) |
Operating environment |
Temperature: 5 to 40°C (41 to 104°F) humidity: 35 to 80 % (no condensation) |
Accessories |
Operation panel: 1, Operation-panel connector cable: 1, Power cord: 1, Depth regulator nose unit: 1, Solid collet : 1,